Universities & schools

BMS for universities & schools

Modern building automation in schools has to meet a multitude of requirements

  • Providing an optimal learning environment
  • Maximum user comfort with efficient use of energy
  • No or minimal impact on the environment
  • Cost reduction

Save costs by need-based control of the room temperature

Inefficient heating causes costs and harms the environment. In order to keep the costs as well as the environmental impact low, it is only recommended to heat when the room is actually occupied. This can be achieved by presence detectors in the rooms or schedules (e.g. based on the timetable). In addition, with the help of window contacts, the temperature can be lowered when one or more windows are open. At night, the temperature is lowered due to time programs.

Constant light control for optimal lighting

By adding or removing artificial light, the illuminance in the room is kept constant depending on the amount of daylight (setpoint). Since only so much artificial light as needed is used, this measure has a positive effect on the costs. Another possibility for cost and energy saving is the automatic switching off of all lights, if a room is not occupied.

Presence detector on aisles and in front of inputs and outputs

Light is only switched on when a person enters the area covered by the presence detector. The automatic shutdown after a certain period of time can save important resources.

Quick problem solving through remote monitoring

By means of remote monitoring of the lighting, heating and, if necessary, blinds, an alarm can be sent to the caretaker in the event of a fault or an exceeding/undershooting of defined thresholds.

Energy reporting for resource optimization

The recording and analysis of the actual consumption values helps to uncover energy saving potentials and to derive optimization measures.

Lighting

HVAC

Shading

Trends/reports

Alarm management

Hotelmanagement

Door locking systems

Security

KNX - BACnet - Modbus - DALI

NUS-SDE4

Singapore

NETx BMS Server, NETxVoyager
Data points: 1,000
Group addresses: 500
Visualization: 500 elements / 10 pages
Trades: lighting, HVAC
System integrator: DGLUX PTE LTD

This project is located in the Net Zero Energy Building in Singapore. The NETx software is used to control and monitor various areas, such as corridors, toilets and classrooms. The project is an ongoing task where faculty members explore Net Zero. Therefore, the control system is always extended with modules and devices.

Schools Mannheim
Mannheim, Germany
BBS Bau- und Betriebsservice GmbH